Model No.︰62.9V17S Packs
Brand Name︰BEST
Country of Origin︰China
Unit Price︰-
Minimum Order︰1000 pcs
Features:
1.Protection Circuit Board for 71.4V 17S 40A Li-ion and Li-polymer battery pack;
2.BMS applies for 17 cells Li-ion/Li-polymer battery pack;
3.To prevent the battery packs from overcharge,overdischarge,over current, over temperature ,short circuit ;
4.With cell balance/equilibrium function;
5.Compatible with both Li-ion and Li-Polymer cells.
6.How balancing function works? after battery pack is fully charged. PCM will detect each cell's voltage and trim higher voltage down until other cells reach the same voltage level. Therefore, it helps cells have longer service life.
(Note: the pictures or parameters in this data sheet are only for your reference, those possibly could be different from the ones you will order. Due to the upgrading of the Hardware/Firmware/Software,Characteristics subject to change without notice, for more information, please contact our technical engineers by email: tech@sunbesthk.com
Specifications:
Item |
Contents |
Criteria (Adjustable from software/hardware) |
|
1 |
Model |
BEST-#### |
17S |
2 |
Voltage |
Charging voltage |
71.4V |
3 |
Current |
Maximal continuous charging current |
80A (adjustable from hardware) |
Maximal continuous discharging current |
80A (adjustable from hardware) |
||
Current consumption |
≤200μA
|
||
4 |
Overcharge Protection |
Over charge detection voltage |
Adjustable from software |
Over charge detection delay time |
Adjustable from software |
||
Over charge release voltage |
Adjustable from software |
||
5 |
Over Discharge Protection |
Over discharge detection voltage |
Adjustable from software |
Over discharge detection delay time |
Adjustable from software |
||
Over discharge release voltage |
Adjustable from software |
||
6 |
Over Current Protection |
Over current detection voltage |
Adjustable from software |
Over current detection current |
Adjustable from software and hardware |
||
Detection delay time |
Adjustable from software |
||
Release condition |
Adjustable from software |
||
7 |
Short Circuit Protection |
Detection condition |
Adjustable from software |
Detection delay time |
Adjustable from software |
||
Release condition |
Cut load, automatically recover |
||
8 |
Balance On @ ≥50mV±5mV OFF @ ≤30mV±5mV |
Balance voltage for single cell |
Adjustable from software |
Balance current for single cell |
Adjustable from hardware |
||
9 |
Resistance |
Inner resistance |
≤20mΩ |
10 |
Temperature |
Single cell temperature when discharge (over temp. protection) ≥65℃ |
Adjustable from software |
Single cell temperature when discharge (low temp. protection) <-40℃ |
Adjustable from software |
||
Single cell temperature when Charge (over temp. protection) ≥50℃ |
Adjustable from software |
||
Single cell temperature when Charge (low temp. protection) <0℃ |
Adjustable from software |
||
11 |
Fuel/Gas gauge |
Display with LEDs |
Thru one button to check capacity |
Self-consumption in different working modes:
· Normal Operating Mode: 13mA typical, 18mA maximum self-consumption.
· Sleep Mode: 200μA typical, 300μA maximum self-consumption.
· The system automatically back to normal operating mode from sleeping mode if current is <2A after no communication signal for 60mins.
· The system also will be back from sleep mode to normal operating mode if any charge or discharge activity is detected or if there’s communication signal again
Voltage protection
· As soon as one cell’s voltage exceeds the protection point, the charging process will be interrupted on the whole pack. The protection circuit returns to normal conditions as soon as all the cell’s voltage falls back to normal. Thedischarge will be allowed and the cell balancing will be activated.
As soon as one cell’s voltage is under the protection point, the discharging process will be interrupted on the whole pack, BMS will be in energy-saving mode, The protection circuit returns to normal operation mode as soon as all the cell’s voltage charged back to normal. When BMS protected up on discharging, the charging processing is still allowed.
Current protection
Software:As soon as the discharging current exceeds the over current detection current during the detection delay time, the discharging process will be interrupted. The BMS returns to normal conditions after over current detection current released.
Hardware:As soon as the discharging current exceeds the over current detection current during the detection delay time, the discharging process will be interrupted. The BMS returns to normal conditions after over current detection current released.
ESD:Battery is protected against electrical discharges:
- 15kV air
- 8kV contact
Price Terms︰ FOB SHENZHEN
Payment Terms︰ TT/PAYPAL/WEST UNION/ESCROW
Packing︰ EXPORT CARTON BOX
Lead Time︰ 7 BUSINESS DAYS AFTER RECEIVE YOUR PAYMENT