Item
|
Contents
|
Criteria
|
1
|
Model
|
HCX-2111V1
|
PCM with FPC
|
2
|
Voltage
|
Charging voltage
|
4.2V
|
3
|
Current
|
Maximal continuous charging current
|
2A
|
Maximal continuous discharging current
|
2A
|
Current consumption
|
≤7μA
|
4
|
Overcharge Protection
|
Over charge detection voltage
|
4.28V±25mV
|
Over charge detection delay time
|
700 ~ 1300ms
|
Over charge release voltage
|
4.08±50mV
|
5
|
Over Discharge Protection
|
Over discharge detection voltage
|
2.30±73mV
|
Over discharge detection delay time
|
14-26mS
|
Over discharge release voltage
|
3.0±80mV
|
6
|
Over Current Protection
|
Over current detection voltage
|
0.125V
|
Over current detection current
|
2A-5A
|
Detection delay time
|
≤16mS
|
Release condition
|
Cut load,automatically recover
|
7
|
Short Circuit Protection
|
Detection condition
|
Exterior shot circuit
|
Detection delay time
|
≤500uS
|
Release condition
|
Cut load,automatically recover
|
8
|
Balance
|
Balance voltage for single cell
|
/
|
Balance current for single cell
|
/
|
9
|
Resistance
|
Inner resistance
|
< 100mΩ
|
10
|
Temperature
|
Operating temperature range
|
-40 ~ +85°C
|
Storage temperature range
|
-40 ~ +125°C
|
11
|
Size (L*W*H)
|
69.9mm* 38.6mm* 0.1 mm
|